Click on the Following Links to Receive Miami-Dade County's Notices of Acceptance.
Egress windows
The Building Codes require certain rooms, mostly bedrooms in residences, to have incorporated at least a window with a size that will allow a person to exit or firefighter to enter through it. Local regulations vary, so you'll need to start with a visit to your Code Compliance Office. With minor variances, here's what you'll find:
-As for size requirements, a window with a minimum opening of 5.7 sq. ft. is needed.
-This opening must have a minimum width of 20" and a minimum height of 24".
-The window sill must be located no higher than 42".
-For floors other than ground, the window sill must be located no lower than 36" from floor.
-Locking devices must be placed no higher than 54" from the floor.
All of the above must be met; otherwise your window will not be considered an
EGRESS WINDOW.
Frame Color: Available in White, Bronze and clear anodized Frames.
Glass colors are clear, gray, green, bronze, & obscure.
French Door
Elegant doors used in patio and pool areas. They can also be used as front doors. Also known as swing doors, they are only manufactured to swing out.
Full View
|
Full - Colonial
|
Piccolino
|
More Info
More Info
These are our standard sizes, custom sizes are available upon request.
CODE |
SIZE |
SIDELITES |
2/0 X 6/8 |
26 X 80 |
12 X 80 |
2/6 X 6/8 |
31 5/8 X 80 |
24 X 80 |
2/8 X 6/8 |
33 5/8 X 80 |
36 X 80 |
3/0 X 6/8 |
37 5/8 X 80 |
5/0 X 6/8 |
60 X 80 |
6/0 X 6/8 |
72 X 80 |
AND ANY SIZE IN BETWEEN MAX 36" ON SIDELITES
CODE |
SIZE |
SIDELITES |
2/0 X 8/0 |
26 X 96 |
12 X 96 |
2/6 X 8/0 |
31 5/8 X 96 |
24 X 96 |
2/8 X 8/0 |
33 5/8 X 96 |
36 X 96 |
3/0 X 8/0 |
37 5/8 X 96 |
AND ANY SIZE IN BETWEEN MAX 36" ON SIDELITES